DC40H Series
Product Appearance
Specifications
NO. |
Item |
Specs |
1 |
Dimension and weight |
84.5mm*61.8mm*43.8mm; 220g |
2 |
Installation dimension |
84.5mm*65mm*46mm; |
3 |
External diameter of outlet |
8MM |
4 |
External diameter of inlet |
11MM |
5 |
Driving mechanism |
Brush-less, magnetic isolated design |
6 |
Material of pump shell |
ABS,PES/SPS/PPS/PA66+30%GF (Optional) |
7 |
Condition of use |
Can continuously work, submersible or land use (not self-priming) |
8 |
Suitable medium |
Water, oil, or normal acid/ alkaline liquids
(Pre-test needed for special liquid) |
9 |
Max working temperature |
60℃ |
10 |
Power consumption |
2.5W~28.8W |
11 |
Rated voltage |
12Vdc or 24Vdc |
12 |
Working voltage range |
5Vdc ~ 12Vdc(Max 14v) or 5Vdc ~ 24Vdc(Max 26v) |
13 |
Max load current |
1.2A |
14 |
Max horizontal flow rate |
7.5L/MIN |
15 |
Max static lift |
11M |
16 |
Noise class |
<40dB |
17 |
Waterproof class |
IP68(suitable for submersible installation) |
18 |
Life span |
Can be more than 30,000hrs |
19 |
Power supply |
Suitable for solar panel, batteries, adapter or other power source |
20 |
Protection function |
dry-run protection, stuck protection(customized function) |
21 |
Power regulation function |
Speed can adjustable by PWM signal, 0~5V analog signal or potentiometer (customized function) |
22 |
Feature |
- small size with high efficiency,maintenance-free
- Use ceramics shaft and carbon fiber sleeve
- Completely water proof (IP68)
- Brush-less dc control without pollution, long life span
- OEM and ODM service accept
- Offer Pump related control system design
|
Pump Structure
Electrical parameters (only for reference,parameters can be customized for specific requirements)
Model No. |
Voltage |
Max load current |
Max static lift |
Max flow rate |
Power consumption |
V(dc) |
A |
M |
L/H |
w |
DC40H-1240 |
12 |
0.50 |
4.0 |
270 |
6.0 |
DC40H-1265 |
12 |
1.2 |
6.5 |
360 |
14.4 |
DC40H-1890 |
18 |
1.20 |
9.0 |
420 |
21.6 |
DC40H-2490 |
24 |
0.90 |
9.0 |
420 |
21.6 |
DC40H-24110 |
24 |
1.20 |
11.0 |
450 |
28.8 |
NOTE |
- Information including continuous working time, working temperature and medium is required to be pre-confirmed with professionals; pump cannot work with high temperature or corrosive fluids.
- When pump is connected into circulation system, load current will be reduced to 70~85% of Max working current (opening outlet current).
- The head means the Max vertical lifting height of water,the flow is 0L/MIN@max head.
- The max flow rate means flow rate with no lifting height(according to the curve bellow)
|
Flow rate-Head Curve
Dimensions of pump